  • release: ESP32-S3 firmware v0.6.5 — Tmr Svc stack + OTA init refactor (#628)

    frostbyte_neo 发布于 2026-05-18 21:05:35 +00:00

    Three fixes wrapped for the v0.6.5-esp32 release tag:

    1. sdkconfig.defaults adds CONFIG_FREERTOS_TIMER_TASK_STACK_DEPTH=8192.
      The fix was already in sdkconfig.defaults.template (ADR-081, prevents
      "stack overflow in task Tmr Svc" bootloop when adaptive_controller emits
      feature_state from inside a Timer Svc callback). It was MISSING from the
      canonical sdkconfig.defaults file used by the build, so any fresh
      build picked up the 2 KiB FreeRTOS default and bootlooped on hardware.
      Verified on COM7: with the fix, no panics in 30 s of operation; without
      it, "ERROR A stack overflow in task Tmr Svc has been detected."
      followed by sustained bootloop.

    2. ota_update.c extracts ota_load_psk_from_nvs() and calls it from
      both ota_update_init() and ota_update_init_ex().
      main.c:230 uses
      the _ex variant, but only ota_update_init() was loading the PSK
      from NVS. Result: s_ota_psk stayed empty regardless of NVS contents,
      so the RuView#596 fail-closed posture rejected every request — but the
      diagnostic warning never printed at boot, leaving operators no signal
      about why their OTA uploads were 403'ing. Verified on COM7:
      W (3126) ota_update: NVS namespace 'security' not found —
      OTA upload endpoint will REJECT all requests until provisioned.
      Fail-closed per RuView#596.

    3. version.txt: 0.6.4 → 0.6.5, paired with the v0.6.5-esp32 tag so the
      firmware-ci version-guard job (RuView#505 fix-marker) stays happy.

    Both validations done end-to-end on hardware (COM7, ESP32-S3 8MB,
    provisioned with --edge-tier 2 to also incidentally re-verify #438 is not
    reproducible on current main).