-
v0.2.0.1 — gate runtime applies on Windows VM boot completion
发布于
2026-04-26 12:04:26 +00:00 Fixed: apply cascade collapsed on cold container. Container RUNNING
state did not mean the Windows VM inside QEMU was ready to accept
FreeRDP RemoteApp activation. Within the 30-90s boot window every
apply collapsed (ERRCONNECT_CONNECT_TRANSPORT_FAILED rc=147 or
ERRCONNECT_ACTIVATION_TIMEOUT rc=131), 3min cascade surfaced as a
Launch Error dialog or '3 of 3 applies failed' panic.Added: wait_for_windows_responsive() probe gates ensure_ready
warm path, winpodx pod apply-fixes, and winpodx migrate's apply
step. _self_heal_apply() swallows transient channel failures in
the warm-pod self-heal context so they don't bubble into Launch
Error dialogs.下载附件